Ocala, Florida 352-640-2936 info@collabplasticdesigns.com
DVS 2205 welded|Hydro & spark tested|Made in USA
Collab Plastic Designs
Request a Quote

PRODUCTS  ·  01 POWER GENERATION

DEF / Urea Storage Tanks

Polypropylene or HDPE tanks for Diesel Exhaust Fluid (DEF / urea), built to the footprint of your enclosure, sub-base, or pad. ISO 22241 compatible, with NPT ports placed where your dosing system needs them, in capacities from compact day tanks to 600-gallon-plus cutout tanks.

DWG NO. YOURS-01REV ADRAWN BY: COLLAB

YOUR CAPACITY. YOUR FOOTPRINT. YOUR PORT LAYOUT.

ISO 22241 COMPATIBLEPP OR HDPE1/2″ OR 3/4″ EXTERIOR WALLSANY FOOTPRINT TO 1/8″NPT PORTS 1/4″ TO 6″

AT A GLANCE

A DEF / urea tank that fits the space you have, not the space a catalog assumes.

Rotomolded DEF tanks come in fixed sizes. Ours are welded from sheet to your drawing, so the tank fills the stub area, the deck, or the enclosure bay you actually have.

MATERIAL
Black copolymer polypropylene (PP) or high-density polyethylene (HDPE) sheet, UV-stabilized; chosen by your specification
EXTERIOR WALLS
1/2″ standard; 3/4″ where the design calls for it. Internal partitions are sized to the design
SIZE
Built to your footprint and capacity, to the 1/8″
PORTS
Flush NPT-tapped ports in the lid, 1/4″ to 6″, located to your drawing; six 2″ ports standard. Double-tap bushings available by request
LIFTING
Lifting pegs with 2″ galvanized eye bolts, quantity as required; stainless D-rings optional
COMPATIBILITY
Wetted surfaces compatible with Diesel Exhaust Fluid per ISO 22241
CONSTRUCTION
Extrusion welded inside and out to DVS 2205 / 2207 practice; partitions where the design requires
TESTING
Hydrostatic and spark tested before shipment
IDENTIFICATION
Tank ID, capacity, date of manufacture, and Made in USA marked on every tank
LEAD TIME
Averages under 6 weeks after approved drawings
WARRANTY
3-year limited warranty (SPEC_0100)

STANDARD ON EVERY TANK

  • Copolymer polypropylene, black, UV-stabilized, smooth; 1/2″ exterior walls
  • Six 2″ flush NPT tapped ports with plugs
  • Extrusion welded inside and out to DVS standards
  • Tank ID, capacity, date of manufacture, and Made in USA on every tank
  • 2″ galvanized eye bolts, quantity as required
  • 3-year limited warranty

OPTIONS & ACCESSORIES

Configure it the way your system needs it.

Select an option to preview its typical location on a rendered tank. The options listed here are the same ones we quote and detail on your submittal drawing. Additional options available to fit your project. Just ask.

ILLUSTRATIVE RENDERING. OPTION LOCATIONS AND HARDWARE ARE FINALIZED ON YOUR SUBMITTAL DRAWING.

SELECT AN OPTION TO PREVIEW IT ON THE RENDERING

TYPICAL INSTALLATIONS

Built to the space the package gives you.

In the sub-base cutout

The designated cutout at the end of a UL 142 / UL 2085 sub-base diesel tank, typically 65 to 140″ wide and 24 to 40″ tall. We build the tank to the cutout so the space holds the most DEF it can.

LENGTH: THE SPACE YOU HAVEH

Alongside the enclosure

A footprint-matched tank on the pad beside the enclosure. We size it to the length you have, keep the profile low, and place the fill and dosing ports on the service side.

COVER: DEFINED SIZEFOOTPRINT: TO YOUR DRAWINGCLEARANCE

Under a covered deck

A covered pad, on a rooftop or at grade. The cover sets the height and the pad sets the footprint; we hold both, down to the 1/8″.

QUESTIONS WE GET

What genset packagers ask before the first order.

Can you fit our tanks in the designated cutout area of a sub-base diesel tank?

Yes. Send the cutout dimensions (length, width, height) and the capacity you need, and we return a quote with a rendering of the tank in that space. The tank is drawn to the opening with clearance for the lifting hardware and fittings.

Polypropylene or HDPE for DEF?

Both are compatible with DEF per ISO 22241. Most of our DEF tanks are copolymer polypropylene; HDPE is available when your specification calls for it. The material is chosen by your spec, not by the tank style.

What do you need for a quote?

A drawing if you have one. If not, the footprint, the height limit, the capacity, and the port sizes you need. Quantity and mounting details help.

When will Collab provide a submittal drawing?

After the quote is approved we will provide a submittal drawing with overall tank dimensions, port sizes and locations, lifting points, and selected options. After your approval your tank will enter our production process.

DOCUMENTS

For your submittal package.

Need something specific for a purchasing or quality file? Email us and we will provide what is required.

GETTING STARTED

Send us a specification or a drawing.

That is all it takes to start. You get a quote with a rendering of your tank, then a submittal drawing with every port placed and every dimension finalized before we cut sheet.

01

You send a spec or a drawing

A formal drawing, a sketch, or just the footprint, capacity, and fluid. Port sizes, mounting, and quantity help if you have them.

02

We return a quote with a rendering

Your tank drawn to your dimensions, so you can see the fit before you commit.

03

You approve a submittal drawing

Ports placed, features selected, dimensions finalized. Production starts on your approval.

NO MOLDS  ·  NO MINIMUM ORDERS  ·  A REAL PERSON ON THE PHONE